Mac 1200 Ecg Machine Manual



Manual

GE MAC 1200 Resting ECG System

The MAC 600 enables physicians to bring advanced ECG analysis to patients they could never reach before. With leading clinical technology and an SD card that puts vital data right in your hands. With on-screen results that help save time, energy, and paper. GEHealthcare MAC™2000ECGAnalysisSystem Operator'sManual SoftwareVersion1.1 2053535-002RevisionC English ©2013GeneralElectricCompany.

Mac 1200 Ecg Machine User Manual 5891 The MAC 1200 Resting ECG System offers a comprehensive solution. The MAC 1200 is a compact 12-lead electrocardiograph designed for acquisition - with or without analysis. The system can be configured as a basic electrocardiograph without analysis for facilities with minimal ECG requirements. Ge filter pane complete w/glue frame (lcd display cover) features: filter pane complete w/glue frame (lcd display cover) for ge mac 12-001 filter pane, glue frame for ge mac 12-001.

What is an ECG System?

Electrocardiography commonly referred to as either ECG or EKG is the recording of electrical activity from the heart over a period of time. The electrical activity is recorded with electrodes that are placed on the skin. Electrodes detect little electrical changes on the skin that arise from the heart muscle’s electrophysiology pattern of depolarizing and re-polarizing during each heartbeat. This process is called a cardiology test.

The electrodes are placed on the patient’s limbs and on the surface of the chest. On a typical 12-lead ECG the overall magnitude of the heart’s electrical potential is then measured from twelve different angles. Over a period of ten seconds, the overall magnitude and directions of the heart’s electrical depolarization is captured at each moment throughout the cardiac cycle. The graph depicted by the ECG system is called an electrocardiogram.

Overview of the GE MAC 1200

The GE MAC 1200 is a digital 12-lead EKG Machine that offers comprehensive ECG solutions. The MAC 1200 offers practical features that help meet the demanding needs of hospitals, clinics, office-based practices, and clinical trials. Its advanced algorithm capabilities, seamless connectivity to the CS and MUSE Cardiology Information Systems and easy-t0-use features; provide maximum quality and convenience. Resting ECGs acquired in the 12-lead mode, and the corresponding data, can then be transmitted to a PC, CardioSys system, or to a MUSE CV system. This EKG Machine is equipped with electronic utilities that ensure artifact-free recordings. Among these are the automatic baseline adjustment and the anti-drift system (Cubic Spline and ADS).

Ecg

General Use of the GE MAC 1200

In the beginning of the recording, the automatic baseline adjustment algorithm verifies the incoming signal and adjusts the baseline position accordingly. During the recording, the anti-drift system (cubic spline) continuously checks the baseline position and returns it to the normal level if required. For manual mode, the anti-drift system (cubic spline) can be enabled and disabled from the setup menu. In the 12-lead and arrhythmia modes, it is always enabled.

GE MAC 1200 Features

  • This system can be configured to meet the needs of hospitals, clinics, and office-based practices
  • Allows access to EKG data gathered throughout a provider network, assuring high quality and continuity of care
  • Comprehensive solution for EKG requirements
  • Waveform LCD display
  • Interpretive EKG
  • Full-size paper reports
  • Portable with a built-in battery
  • Measurements, interpretation, and memory available in any combination
  • Simultaneous 12-lead ECG acquisition and analysis
  • Compact, lightweight design with carrying handle
  • Field upgradability

GE MAC 1200 Specifications

Signal Processing:

  • Acquisition: 12 leads – simultaneously.
  • Signal input: Type CF according to IEC.
  • Digital sampling rate: 1000 samples/second/channel.
  • Dynamic range: Differential signals for AC voltage ±, 10mV Superimposed DC voltage (Polarization voltage) ±600mV.
  • Resolution: 5 uV.
  • Frequency response:0.04 – 150 Hz.
  • Common mode rejection:> 140 dB.
  • Input impedance: > 100 M ohms.
  • Leakage current: < 10uA.
  • Pacemaker detection sensitivity: All leads, duration 0.1 – 2.5 ms, amplitude > 5 mV.

Display:

  • Type: LCD 320 x 240 pixel, backlit, Contrast adjustable.
  • Displayed data: Selected lead group, operation mode, lead check, heart rate, AC filter, muscle her, ADS, gain, speed, name, ID, 3 ECG waveforms.

Ge Mac 1200 Ecg Machine Manual

Writer:

  • Type: Thermal array print head.
  • Resolution: Vertically 8 dots/mm horizontally 25um at 25 mm/s.
  • Paper: 8.5 x 11 inch.
  • Writer speed: 5, 25, 50 mm/s.
  • Paper type: Z-fold.

Keyboard:

  • Type: Membrane keypad with tactile feedback / 46 keys.

Special Functions:

  • Anti Drift System (ADS): Automatic compensation of baseline fluctuations caused by polarization voltage fluctuations at the electrodes.
  • Baseline adjustment: ECG presentation on the averaged baseline.
  • Electrode monitoring: Audible and visual indication on the LCD of disconnected electrodes or fine break. Every single electrode is monitored.
  • Copy: In the automatic 12 lead modes, after ECG, recording, copies of the ECG can be printed.
  • Test: Automatic performance test upon power up, including verification of the signal path starting at the signal input.

Power Supply:

1200
  • Ratings: 10 – 120 V (0.32A) / 220 – 240 V (0.16A).
  • Frequency: 49 – 65 Hz.
  • Battery type: NiCad, 18V, 1.4 Ah.
  • Battery charge time: 4 hours.

Physical Specs:

  • Width: 14.5 in. (370 mm)
  • Height: 3.7 in. (94 mm)
  • Depth: 12.6 in. (320 mm)
  • Weight: 12.4 lb. (5.6 kg) with graphics display and battery.

Have you used this product before? What features do you like? Comment below!

MAC1200 ECG Machine


mac_1200_ecg_machine_.pdf

The MAC1200 ECG machine offers a comprehensive ECG solution with practical features that meet the needs of hospitals, clinics, office-based practices and clinical trials. The MAC1200 provides resting ECG's with measurements and interpretation at its most basic level. It also has the facility to provide continuous ECG monitoring of arrhythmia with event documentation and final report.
Stress test program compatible with the MUSE® and CardioSoft® systems (optional).


The GE Mac1200 ECG machineis available for rental / hire or purchase


Features

  • LCD screen for viewing traces
  • Automatic, 12 lead simultaneous acquisition
  • Manual, real time 6-channel
  • Arrhythmia, continuous monitoring with event documentation
  • One touch operation for acquisition, analysis, storage and printing minimises training
  • 4 user-definable fields for patient data entry flexibility
  • Portable, lightweight design with carry handle
  • Full size paper accommodates multiple standard report formats
  • Mains and battery operation with automatic recharge
  • Fully charged battery will provide up to 50 ECG's
  • 40 ECG memory software (optional)
  • Stress Test software (optional)
  • Operating modes:
    • Automatic, 12 lead simultaneous
    • Manual, real-time 6-channel
    • Arrhythmia, continuous monitoring with event documentation
    • Stress test (optional)


Specification

Ge mac 1200 ecg machine manual
Display
LCD 320 x 240 pixel, backlit, contrast adjustable
Power supply
95 to 240V, 49 - 64 Hz
Battery operation
NiCad, 18V, 1.3 Ah
Battery charge time
Approximately 4 hours from total discharge
Operating temperature
10 to 40°C
Storage temperature
-30 to 60°C
Operating humidity
25 - 95%
Storage humidity
25 - 95%
Operating pressure
700 to 1060 hPa
Storage pressure
500 to 1060 hPa
Weight
5.6 kgs with battery installed
Dimensions
94h x 370w x 320d mm


Prices

Our range of ECG Monitoring Equipment is available on a rental, purchase or equipment management basis - please use the links at the top of the page to request a quotation.

Mac 1200 Ecg Ekg Machine System Manual

Please contact us if you cannot find a solution to your ECG monitoring requirements. We have a wide range of equipment available including Stress Test Systems, Holter monitors and Event recorders.


Mac 1200 St Ecg Machine Manual


Specialists in the supply and management of ECG Monitoring

Clinical Trial Outsourcing | Clinical Trials Equipment | Equipment Outsourcing